Page text
Hilti (Canada) Corp. 1-800-363-4458 • www.hilti.ca • Hilti Firestop Systems Guide • 05/2011 Hilti. Outperform. Outlast. Introduction Appilcations/Products Selector Guide Through-Penetration Joint Reference Data Estimating Tables TABLE 1 Top of wall joint estimation table for CP 601S, CP 606 and CP 506 (Fluted deck only — deck ribs perpendicular to wall) Joint Width Size of Metal Flute OLQHDOIHHWR]WXEH OLQHDOIHHWR]WXEH OLQHDOIHHWR]WXEH 2.2 lineal feet/600 ml foil pack 2.1 lineal feet/600 ml foil pack 1.5 lineal feet/600 ml foil pack 14.1 lineal feet/gallon 13.5 lineal feet/gallon 10.0 lineal feet/gallon Estimations based upon 1/2" product depth on both sides of the wall. For 1/4" depth, multiply values by 2. All estimates are approximate and assume no waste. Estimates may vary depending on deck type. TABLE 2 Top of wall joint estimation table for CP 601S, CP 606 and CP 506 (Fluted deck only, gypsum cut to fit deck profile — deck ribs perpendicular to wall) Joint Width Size of Metal Flute OLQHDOIHHWR]WXEH OLQHDOIHHWR]WXEH OLQHDOIHHWR]WXEH 3.5 lineal feet/600 ml foil pack 4.0 lineal feet/600 ml foil pack 3.6 lineal feet/600 ml foil pack 23.2 lineal feet/gallon 26.1 lineal feet/gallon 23.6 lineal feet/gallon Estimations based upon 5/8" product depth on both sides of the wall. For 1-1/4" depth, divide values by 2. All estimates are approximate and assume no waste. Estimates may vary depending on deck type. TABLE 3 General joint estimation table for CP 601S, CP 604, CP 606 and CP 506 (floor to floor, floor to wall, wall to wall, top of wall) Joint Width Lineal Feet/10.5 oz. Tube Lineal Feet/600 ml Foil Pack Lineal Feet/Gallon Sealant Depth (in.) Sealant Depth (in.) Sealant Depth (in.) For wall to wall and top of wall joints, one side of the wall only, divide values by 2 to estimate for both sides of wall. All estimates are approximate and assume no waste. TABLE 4 Top of wall joint estimation table for CFS-SP WB Firestop Joint Spray and CP 572 (Top of wall with fluted deck) Joint Width Size of Metal Flute 38.5 lineal feet/gallon 34.2 lineal feet/gallon 28.0 lineal feet/gallon 34.2 lineal feet/gallon 30.8 lineal feet/gallon 25.6 lineal feet/gallon 30.8 lineal feet/gallon 28.0 lineal feet/gallon 23.6 lineal feet/gallon 28.0 lineal feet/gallon 25.6 lineal feet/gallon 22.0 lineal feet/gallon 23.6 lineal feet/gallon 22.0 lineal feet/gallon 19.2 lineal feet/gallon 20.5 lineal feet/gallon 19.3 lineal feet/gallon 17.1 lineal feet/gallon 18.1lineal feet/gallon 17.1 lineal feet/gallon 15.4 lineal feet/gallon 16.2 lineal feet/gallon 15.4 lineal feet/gallon 14.0 lineal feet/gallon 14.6 lineal feet/gallon 14.0 lineal feet/gallon 12.8 lineal feet/gallon Estimations based upon 1/8" product depth with 1/2" overlap and installation on both sides of the wall. For 1/4" depth, divide values by 2. (Note: Quantities may change when used in conjunction with fireproofing material. Refer to specific firestop system for details.) All estimates are approximate and assume no waste. Estimates may vary depending on deck type. Estimating tables for joints