Fireblock CFS-BL — page 1385

Page text

Product Information
Hilti (Canada) Corp. 1-800-363-4458 • www.hilti.ca • Hilti Firestop Systems Guide
Hilti. Outperform. Outlast.
Hilti Firestop
Saving lives
through innovation
and education
Firestop Block
CFS-BL
Product description
■
■Ready-to-use, intumescent flexible block designed to seal medium
to large size openings
Product features
■
■Integrated “Grid-Tech” increases Annular Space up to 12”
■
■Suitable for re-penetration or new penetrations
■
■Economical to use with short installation times
■
■Easy installation — no special tools required
■
■Ideal for use in floors — no forming required
■
■One sided wall systems available
■
■Halogen, asbestos and solvent free
■
■Operational immediately after installation
■
■Smoke resistant
Areas of application
■
■Sealing single or multiple penetrations in small to large openings
■
■Temporary or permanent sealing of cables and cable tray
penetrations
■
■Temporary or permanent sealing of insulated and non‑insulated
metallic pipes and combustible pipe penetrations
For use with
■
■Walls (UL tested up to max. opening 72" x 36")
■
■Floors (UL tested up to max. opening 72" x 36")
■
■Concrete, porous concrete, masonry and gypsum wall assemblies
■
■Wall assemblies rated up to 4 hours
■
■Floor assemblies rated up to 3 hours
Examples
■
■Completely dust and fiber free rooms and places where electrical
installations are frequently used (ie: computer centers, hospitals,
laboratories, etc.)
■
■New buildings in the construction phase and during renovation
■
■Large openings containing multiple penetrations as found in
production bays, warehouses, hospitals etc.
Installation instructions for Firestop Block CFS-BL
FILL, VOID OR CAVITY MATERIALFOR USE IN THROUGH-
PENETRATION FIRESTOP SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
66Y7
FM
APPROVED
Notice
•	Before handling, read Material Safety Data Sheet and
product label for safe usage and health information.
•	Instructions below are general guidelines — always
refer to the applicable drawing in the UL Fire
Resistance Directory or Hilti Firestop Systems Guide
for complete installation information
Opening
1.	Clean the opening. Penetration and penetration
supporting structures must be installed in
compliance with local building and electrical
standards.
Application of Firestop Blocks
2a.If no penetrations are located, build up Firestop
Block CFS-BL, firmly seated, within opening.
2b.If penetrations are located, build up Firestop Block
CFS-BL, firmly seated, while cutting blocks with a
knife to suit the placed penetrations.
3.	Finish building up Firestop Blocks until entire
opening is filled.
4.	Completely fill cable spaces, gaps between blocks
and pipes, and joints with FS-ONE Firestop Sealant
(as required).
5.	For maintenance reasons, a penetration seal could
be permanently marked with an identification plate.
In such a case, mark the identification plate and
fasten it in a visible position next to the seal.
Re-installing cables or other penetrations
•	Remove or cut the block from the seal.
• 	Install the penetrant and re-lay the block in
compliance with the approval. Fill gaps and spaces
with FS-ONE Firestop Sealant (as required).
Single cables can be run through joints between
blocks or a hole can be drilled through a block using
a sharpened piece of metal pipe or tubing.
Not for use
•	In wet rooms, outdoors or exposed to the weather
or UV radiation (can be done only after applying an
additional silicone coating, i.e. CP 601S).
Storage
•	Store only in the original packaging in a location
protected from moisture and direct sunlight
1. Clean opening.
2a. Build up blocks
2b. Cut blocks to
size for penetrations
in place
3. Build up blocks
4. Fill gaps with
FS-ONE, CP 617
or CP 618 putty (as
required).
5. Fasten identification
plate in place (If
required)
Technical Data*
CFS-BL
Color
Red
Application temperature
40° F to 104° F (5° C to 40° C)
Temperature resistance
5° F to 140° F (-15° C to 60° C)
Intumescent activation
Approx. 392° F (200° C)
Expansion ratio (unrestricted)
Up to 1:3
Surface burning characteristics
(ASTM E84-10b)
Flame Spread Index: 10
Smoke Development Index: 15
Sound transmission classification
(ASTM E 90)
STC Rating: 52
Approvals
• California State Fire Marshal - In Progress
Tested in accordance with
• UL 1479     • ASTM E 814     • ASTM E 84     • CAN/ULC S115
*At 73°F (23°C) and 50% relative humidity
NEW
Grid-Tech!